Skip to main content
Version: Next

User Manual

1. Overview

The Rubix Connect LW features a high-performance LoRaWAN® concentrator card seamlessly integrated into a specialised module for use with the Rubix Compute and other IOT systems. A powerful, efficient platform for deploying LoRaWAN® networks. Designed for low power consumption and multi-channel support, it streamlines network setup and scales easily to accommodate various applications such as smart cities, agricultural monitoring, environmental sensing, industrial automation, and smart metering.

The RC-LW-CON-1 is an add-on module to the Nube iO Rubix-Compute. Once plugged into the Rubix Compute this enables the Rubix Compute to run as a LoRaWAN® server.

max400px

2. Technical Specifications

2.1. Power Requirements

Power Options and Requirements:
Power Via TerminalPower Supply: 5VDC supplied through the RJ12 cable from the Rubix compute S-BUS

2.2. Physical Size

max500px

2.3. Communication Options

Communication Options:Part Comms
max200px
RJ12
N/A Edge Connect R12 interface
Provides power and breakout for USB, UART for add-on modules
max200pxAdd in radio model
Supported Frequencies: AU915-92
Spreading Facto 6-12
Bandwidth: 7.8 - 500 kHz
Effective Bitrate: 018 - 37.5 kbps
Est. Sensitivity: -111 to -148 dBm

3. Mounting and Size

3.1. Dimensions

max500px

3.2. Mounting

max500px

4. Power Connection

The Rubix Connect LW is powered through the RJ12 cable.

5. RJ12 Service Port

The RJ12 port is used for the following; Used in conjunction with the Nube iO Edge Compute for IO expansion. (When used for input IO expansion the bus from the Edge Compute can power the Rubix Connect LW)

5.1. RJ12 Drawing

max500px

5.2. RJ12 Cable Selection

RJ12 Cable
max200pxRJ12 cable can be used.
Additionally, the RJ12 connector could supply power to the Rubix Connect LW.
RJ11 will not provide power to the module but can provide comms

5.3. Pin Connections

RJ12 Cable
max200pxPin 1: Power (5V dc)
Pin 2: Enable (EN)
Pin 3: USB Data
Pin 4: USB Data +
Pin 5: Ground (GND)
Pin 6: Ground (GND)

6. Regulatory Compliance

Regulatory
LoRa end node radio● FCC: Class B 3M Radiated